Building standards

Foundation

Reinforced concrete foundation plate

Structural systemKatalog standardů a nadstandardů

Monolithic reinforced concrete skeleton with beamless floor slabs on the below-ground storeys; the supporting structure of the building in the form of a cross-wall construction system on the above-ground storeys

Floor structure

Reinforced concrete plate

Façade

Exterior façade: sandstone slabs, maximally 1,500 x 500 mm in size; interior façade: fibre cement cladding

Lightning conductor

The building is protected by a lightning conductor.

Balcony handrails

Steel handrails with multiple glass panels (toughened glass)

Windows

Wooden Euro windows with Alurol outdoor roller blinds, insulating double glass panes and white metal window fittings

Common corridor flooring, entrance lobby

Ceramic tiles

Common corridor interior plasterwork, entrance lobby

Interior walls, made of Porotherm blocks, have a lime-cement finish; concrete structures will be covered with a thin-layer trowel-on coating with finishing coat surface; staircase walls will have insulating plaster.

Lighting (exterior lighting, corridors, staircases, entrance lobby)

Exterior lighting: the area lighting
Corridor, staircase, entrance lobby: flush ceiling reflectors, controlled by motion detectors and staircase timers

Staircases

Prefabricated and monolithic staircases on the above-ground and below-ground levels respectively

Staircase handrails

Made of steel profiles with a finish

Lift

There are 12 lifts in the entire building, serving all the above-ground and below-ground floors

Garage

2 below-ground floors for clients’ parking spaces; entrances into the garage with a barrier along with a roller door; numbered parking spaces

Interior wiring, meters

Separate meters for common areas

Security

24 hour reception desk and security service; entry card system; the site is surrounded by a fence; security cameras are at the entrances for pedestrians and vehicles

Separating walls (between apartments)

Reinforced concrete walls

Internal walls, partitions between rooms

Made of burnt bricks; gas silicate protective brick skin

Interior plasterwork

Double layer finishing coat

Ceilings

Plasterboard ceilings are in vestibules / entrance halls, toilets, bathrooms and utility rooms.

Windows, French windows

Wooden windows (Euro profiles)

Window sills

Made of wood, white or in the colour of standard flooring

Entrance door

Security full wooden door, security metal frame, Security Class 3; 2,100 mm in height

Interior doors

See the Standards Classic and Modern, 2,100 mm in height

Flooring – habitable rooms, hallways

Bevelled wooden flooring

Flooring – bathrooms, toilets

Tiles

Wall tiling – bathrooms, toilets

See the Standards Classic and Modern

Inner fittings

See the Standards Classic and Modern

Water piping

Plastic pipes

Heating

Double pipe system of hot water heating, with forced water circulation, steel radiators, convectors and bathroom tubular radiators

Sewers

Plastic pipes, rainwater pipes from the terraces

Hot service water system

The exchanger connected to the distribution system of Pražská teplárenská a.s. serves as the central resource of hot water, each apartment has a separate meter.

Meters (electricity)

Electrical meters are on the first above-ground floor of the building.

Light-current wiring

In-house telephone, telephone, the Internet, preparation for cable and satellite TV, self-contained fire detector, preparation for electronic security systems; electronic security systems installed in the ground floor apartments and the apartments with terraces

Air-conditioning

Preparation for cooling in the A Building apartments and the apartments on the top and semi-top floor apartments

Kitchen fitments

Not included in the developer’s contract, the standard specifications include preparation for interior fittings

Flooring – balconies, terraces

Tropical wood grids

Product standards

bathroom,
doors, hardware, floor

download document 4 MB